Design Guide & Applications Manual
For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies
vicorpower.com 800-735-6200 Applications Engineering 1-800-927-9474 Rev. 2.1
Page 27 of 88
9. EMC Considerations
C1 = 100 µF
C2
a
– C2
b
= 4,700 pF (Vicor Part # 01000)
C3
a
– C3
b
= 0.01 µF (Vicor Part # 04872)
C4 = 270 µF (Tant.)
L1 = 200 nH (Vicor Part # 30268)
Conditions
Light Load = 3 A
Nominal Load = 15 A
Full Load = 30 A
+IN
–IN
+OUT
–OUT
C3
a
GATE
IN
GATE
OUT
+S
TRIM
–S
C2
a
C1
C2
b
C3
b
C4
L1
Figure 9–12 — Output noise, additional output inductor and capacitor (L-C Filter)
Output Ripple vs. Load
LC Output Filter
Typical Vicor Module (VI-230-CV) 48 V Input, 5 V Output