EMC Qlogic QLA22xx Guia de Instalação Página 65

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 64
3
Configuring a CLARiiON Boot Device
3-29
Configuring an EMC Boot Device
options, depending on whether you want to disrupt the connectivity
of the host:
Without disrupting Host Connectivity (more complex procedure
using Navisphere CLI):
Note: You must have Navisphere CLI installed. Refer to product notes for
complete usage instructions.
RR:1.Using a command prompt, browse to the Navisphere CLI
directory (typically
C:\Program Files\EMC\Navisphere
CLI>
6. Enter command navicli -h
<sp_IP>
storagegroup
-connecthost -host <
hostname
> -gname
<storagegroupname>
where
<sp_IP>
is the IP address of either array SP;
<hostname>
is the hostname of the host connection to update;
and
<storagegroupname>
is the name of the storage group of
the host connection to update.
7. When prompted, verify the
<hostname>
and
<storagegroupname>
are correct as follows:
Connect host
<hostname>
to storage group
<storagegroupname
> (y/n)?"
Enter Y to proceed.
8. Perform a device rescan on your host, and verify the
additional device paths are present.
With brief disruption of Host Connectivity (simpler procedure
using Navisphere GUI):
RR:1.Shut down the host.
9. Remove the host from the storage group.
10. Apply the change.
11. Add the host back into the storage group.
12. Restart the host.
13. Check the array connectivity status to ensure all connections
you require are active.
QLogic_Windows.book Page 29 Friday, May 27, 2005 3:53 PM